Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Chinese Journal of Experimental and Clinical Virology ; (6): 207-211, 2019.
Article in Chinese | WPRIM | ID: wpr-804723

ABSTRACT

Objective@#To obtain the optimum of lentiviral library packaging based on CRISPR/cas9 (Clustered regularly interspaced short palindromic repeat sequences/CRISPR-associated protein 9).@*Methods@#Reverse transcription polymerase chain reaction (RT-PCR), immunofluorescence antibody (IFA) and enzyme linked immunosorbent assay (ELISA) were used to detect the lentivirus titers in condition of different ratio of packaging plasmids, different addition of lipofectamine 3000 reagent and different time points post-transfection. Then, high-throughput sequencing was performed to evaluate the representation and distribution of single guide (sg)RNAs in the library.@*Results@#The lentivirus titer was the highest when the molar ratio of psPAX2∶pMD2.0G∶Lentivirus library was 2∶1∶1, and the optimum addition of Lipofectamine 3000 reagent was 10 μl, while the result of ELISA were correspondent to that of RT-PCR. The IFA result showed that the lentivirus titer was the highest at 60 h post-transfecion. The coverage of sgRNAs in the lentivirus library packaged with the optimum we obtained was 99.3%, and the read counts of sgRNAs was observed in a normal distribution.@*Conclusions@#The optimal lentivirus library packaging was obtained, and this can provide basis for CRISPR/cas9-based screening.

SELECTION OF CITATIONS
SEARCH DETAIL